Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS > CIRCUIT BREAKERS - GFCI
Sort By:
Go
Page of 1
BREAKER GF PER PROT 5MA PON20A Qwik Open Square D QO GFCI Circuit Breaker Qwik Open Square D QO GFCI Circuit Breaker
Eaton Circuit Breaker, GFCI, Type BR, 120 VAC, 20 A, Number of Phases: 1, Number of Poles: 1, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Center, Long Time, Instantaneous, Trip Sensitivity: 5 mA, Wire Size: 14 to 8 AWG, Terminal Type: Plug-In, Dimensions: 4 in L x 3-1/2 in W x 1 in H, Suitable for: CPM, CPL, CBRPM, CBRPL Load Center All QO circuit breakers are equipped with the Visi-Trip? indicator. When a Visi-Trip circuit breaker trips, the handle snaps to a midpoint position between "OFF" and "ON" and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 60 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical protection. All QO circuit breakers are equipped with the Visi-Trip? indicator. When a Visi-Trip circuit breaker trips, the handle snaps to a midpoint position between "OFF" and "ON" and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 60 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical protection.
BREAKER CIRC GRDFAULT 120V 15A BREAK BR 2PL GFST 120/240V 15A BREAKER CIRCUT 120/240V 40A
Ground fault circuit interrupters are an effective means of preventing severe electrical shock. To protect equipment from damaging ground faults, Siemens GFCIs continuously monitor the difference in current between the hot and neutral conductors. If the electricity going to an outlet equals the current coming back from the outlet, the GFCI is dormant. If the electricity going to an outlet is greater than 5 mA than the current coming back from the outlet, the GFCI will open the circuit to stop of flow of electricity. Eaton Circuit Breaker, GFCI, Type GFTCB, 120/240 VAC, 15 A, Number of Phases: 1, Number of Poles: 2, Interrupt Rating: 10 kA, Actuator Type: Magnetic, Thermal, Trip Type: Common, Long Time, Instantaneous, Trip Sensitivity: 5 mA, Wire Size: 14 to 8 AWG, Terminal Type: Plug-In, Dimensions: 4-1/2 in L x 2-3/4 in W x 2 in H, Suitable for: CPM, CPL, CBRPM, CBRPL Load Center Schneider Electric Circuit Breaker, GFI, 120/240 V, 40 A, 2 Pole, 10 kA Interrupt, Plug Mounting